CONFIGURATION GUIDELINES
Stand-alone and network systems require a main display. The main display must be either NCD, ONYXWorks or one panel in the network with Network Display mode enabled.
MAIN SYSTEM COMPONENTS
CPU-N16LD: N16x with display. Intelligent fire alarm with one SLC loop, 10″ touchscreen display, 4 NACs, and power supply; chassis mounted for use in a CAB-5 Series cabinet.
CPU-N16LND: N16x without display, for use as network node. Intelligent fire alarm with one SLC loop, 4 NACs, and power supply; chassis mounted for use in a CAB-5 Series cabinet.
CPU-16-RTO: N16x with display for use in retrofit cabinets. Intelligent fire alarm with one SLC loop, 10″ touchscreen display, 4 NACs, and power supply; chassis mounted for use in a CAB-4 Series cabinet.
N16E: Intelligent fire alarm panel with one SLC loop, 10″ touchscreen display, 4 NACs, and power supply in a black enclosure.
N16E-R: Intelligent fire alarm panel with one SLC loop, 10″ touchscreen display, 4 NACs, and power supply in a red enclosure.
SLM-318: Signaling Line Module provides a Signaling Line Circuit of 159 addressable points. Add SLM-318 units to expand SLC capability.
NETWORKING OPTIONS
NCD: Network Control Display. On network systems (two or more networked fire panel nodes), one network display is required for every system (either NCD, ONYXWorks, or N16 with Network Display mode enabled). On network systems, the NCD connects (and requires) a standard Network Communication module or High-Speed Network Communication Module.
NCM-W, NCM-F: Standard Network Communications Modules. Wire and multi-mode fiber versions available.
HS-NCM-W(-2), HS-NCM-MF, HS-NCM-SF, HS-NCM-WMF(-2), HS-NCM-WSF(-2), HS-NCM-MFSF: High-speed Network Communications Modules that can connect to two nodes. Wire, single-mode fiber, multi-mode fiber, and media conversion models are available.
RPT-W, RPT-F, RPT-WF: Standard-network repeater board with wire connection (RPT-W), multi-mode fiber connection (RPT-F), or allowing a change in media type between wire and fiber (RPT-WF). Not used with high-speed networks.
ONYXWorks: UL-listed graphics PC workstation, ONYXWorks GUI software, and computer hardware.
NFN-GW-EM-3: NFN Gateway, embedded. (Replaces NFN-GWEM.)
CAP-GW: Common Alerting Protocol Gateway.
VESDA-HLI-GW: VESDAnet high-level interface gateway.
LEDSIGN-GW: UL-listed sign gateway. Interfaces with classic and high-speed NOTI•FIRE•NET networks through the NFN Gateway.
OAX2-24V: UL-listed LED sign, used with LEDSIGN-GW.
AUXILIARY POWER SUPPLIES AND BATTERIES
PMB-AUX: Auxiliary power supply, 6 amps, universal AC input, 4 NACs and 2 Auxiliary outputs, chassis-mounted for use in a CAB-5 Series cabinet. Charges 7-100AH batteries.
PMB-AUX-RTO: Auxiliary power supply, 6 amps, universal AC input, 4 NACs and 2 Auxiliary outputs, chassis-mounted for use in a CAB-4 Series cabinet. Charges 7-100AH batteries.
PSE-6/10: PowerStrike™ Remote 6A/10A power supply with battery charger.
BAT Series: Sealed lead-acid batteries listed for fire-protective service. (Required.)
AUDIO OPTIONS
NOTE: See “Enclosures, Chassis, And Dress Plates” for mounting hardware.
DVC-EM: Digital Voice Command, digital audio processor with message storage for up to 32 minutes of standard quality (4 minutes at high quality) digital audio.
DVC-RPU: Digital Voice Command Remote Paging Unit for use with DVC-EM. Includes the keypad/display.
DS-DB: Digital Series Distribution Board, provides bulk amplification capabilities to the DVC-EM while retaining digital audio distribution capabilities. Can be configured with up to four DS-AMPs, supplying high-level risers spread throughout an installation.
DVC-KD: DVC-EM keypad for local annunciation and controls; status LEDs and 24 user-programmable buttons.
DS-AMP/E: 125W, 25 VRMS, or 100W, 70VRMS. 70VRMS requires DS-XF70V step-up transformer. Digital Series Amplifier, part of the DS-DB system.
DS-RFM, DS-FM, DS-SFM: Fiber conversion modules for DVC-EM, DS-DB distribution board, and DAA2/DAX Series amplifiers.
DAA2-5025(E): 50W, 25 Vrms Digital Audio Amplifier assembly with power supply; includes chassis.
DAA2-5070(E): 50W, 70.7 Vrms Digital Audio Amplifier assembly with power supply; includes chassis.
DAA2-7525(E): 75W, 25 Vrms digital audio amplifier assembly with power supply; includes chassis.
DAX-3525(E): 35W, 25 Vrms Digital Audio Amplifier assembly with power supply, includes chassis.
DAX-3570(E): 35W, 70.7 Vrms Digital Audio Amplifier assembly with power supply, includes chassis.
DAX-5025(E): 50W, 25 Vrms Digital Audio Amplifier assembly with power supply, includes chassis.
DAX-5070(E): 50W, 70.7 Vrms Digital Audio Amplifier assembly with power supply, includes chassis.
TELH-1: Firefighter’s Telephone Handset for use with the DVC-EM when mounted in the CA-2 chassis.
CMIC-1: Microphone used with DVC/DVC-EM. Included with CA-2 chassis assembly.
RM-1/RM-1SA: Remote microphone assemblies, mount on ADP-4 (RM-1) dress panel or CAB-RM/-RMR (RM-1SA) stand-alone cabinets.
DAA Series Digital Audio Amplifiers: Legacy DAA Series amplifiers are compatible with DVC systems running SR4.0.
DAX-3525(E): 35W, 25 Vrms Digital Audio Amplifier assembly with power supply, includes chassis.
DAX-3570(E): 35W, 70.7 Vrms Digital Audio Amplifier assembly with power supply, includes chassis.
DAX-5025(E): 50W, 25 Vrms Digital Audio Amplifier assembly with power supply, includes chassis.
DAX-5070(E): 50W, 70.7 Vrms Digital Audio Amplifier assembly with power supply, includes chassis.
COMPATIBLE DEVICES, EIA-232 PORTS
PRN-7: 80-column printer.
VS4095/5: Printer, 40-column, 24 V. Order from Keltron, Inc.
COMPATIBLE DEVICES, AIO BUS
ACM-30: Fully-customizable annunciator; Independently-configured buttons with up to 60 points of annunciation. LEDs can be programmed to activate in red, green, yellow, white, amber, blue, cyan or purple. Up to 40 annunciators per FACP.
COMPATIBLE INTELLIGENT DEVICES
FSP-951-SELFT: White, low-profile intelligent self-testing photoelectric sensor, FlashScan only.
FSP-951T-SELFT: White, same as FSP-951 but includes a built-in 135°F (57°C) fixed-temperature thermal device, FlashScan only.
FST-951-SELFT: White, low-profile intelligent self-testing 135°F fixed thermal sensor, FlashScan only.
FCO-951/-IV FlashScan, Addressable intelligent multi-criteria smoke sensors, photo, carbon monoxide, fixed temperature heat detector, and infra-red (IR).
FPC-951: FlashScan, Combined photoelectric and carbon monoxide sensor.
FWSG Wireless SWIFT Gateway: Addressable gateway supports wireless SLC devices.
FSCO-951: FlashScan, Addressable carbon monoxide sensor.
FPTI-951, FPTI-951-IV: Addressable intelligent multi-criteria photoelectric, thermal, and IR sensors.
FS-OSI-RI: Addressable intelligent single-ended beam smoke detector.
FSP-951: White, low-profile intelligent photoelectric sensor, FlashScan only.
FSP-951-IV: Ivory, low-profile intelligent photoelectric sensor.
FSP-951T: White, same as FSP-951 but includes a built-in 135°F (57°C) fixed-temperature thermal device. FlashScan only.
FSP-951T-IV: Ivory, same as FSP-951T but includes a built-in 135°F (57°C) fixed-temperature thermal device.
FSP-951R: White, low-profile intelligent photoelectric sensor, remote test capable. For use with DNR/DNRW. FlashScan only.
FSP-951R-IV: Ivory, low-profile intelligent photoelectric sensor, remote test capable. FlashScan only.
FST-951: White, low-profile intelligent 135°F fixed thermal sensor, FlashScan only. Must be mounted to one of the bases listed below.
FST-951-IV: Ivory, low-profile intelligent 135°F fixed thermal sensor, FlashScan and CLIP. Must be mounted to one of the bases listed below.
FST-951R: White, low-profile intelligent rate-of-rise thermal sensor, FlashScan only. Must be mounted to one of the bases listed below.
FSP-951R-IV: Ivory, low-profile intelligent photoelectric sensor, remote test capable. FlashScan only.
FST-951H: White, low-profile intelligent 190°F fixed thermal sensor, FlashScan only. Must be mounted to one of the bases listed below.
FST-951H-IV: Ivory, low-profile intelligent 190°F thermal sensor, FlashScan and CLIP. Must be mounted to one of the bases listed below.
FSV-951, FSV-951R: White, intelligent high-sensitivity photoelectric smoke detector.
FSV-951-IV, FSV-951R-IV: Ivory, intelligent high-sensitivity photoelectric smoke detector.
VEP-A00-P-NTF: Intelligent aspiration smoke detector with LED display, 4 pipes, covers up to 21,520 square feet.
VEP-A10-P-NTF: Intelligent aspiration smoke detector with LED and LCD display, 4 pipes, covers up to 21,520 square feet.
VEP-A00-1P-NTF: Intelligent aspiration smoke detector with LED display, single pipe, covers up to 10,760 square feet.
VEU-A00-NTF: Intelligent aspiration smoke detector with LED display, 4 pipes, covers up to 69,965 square feet.
VEU-A10-NTF: Intelligent aspiration smoke detector with LED and LCD display, 4 pipes, covers up to 69,965 square feet.
VEA-040-A00-NTF: Intelligent aspiration with LED display, 40 point addressable detection points. Covers 36,000 square feet.
VEA-040-A10-NTF: Intelligent aspiration with LED and LCD display, 40 point-addressable detection points. Covers 36,000 square feet.
DNR: InnovairFlex low-flow non-relay duct-detector housing. (Order FSP-951R separately.)
DNRW: Same as above with NEMA-4 rating, watertight.
B224RB-WH: White, low-profile relay base.
B224RB-IV: Ivory, plug-in System Sensor relay base.
B224BI-WH: White, isolator base for low-profile detectors.
B224BI-IV: Ivory isolator detector base.
B300-6: White, standard flanged low-profile mounting base.
B300-6-IV: Ivory, standard flanged low-profile mounting base.
B501-WHITE: European-style, 4″ (10.16 cm) base.
B501-BL: Black, 4” standard European flangeless mounting base.
B501-IV: Ivory color, 4” standard European flangeless mounting base.
B200S-WH: White, intelligent programmable sounder base, capable of producing a variety of tone patterns including ANSI Temporal 3. Compatible with synchronization protocol.
B200S-IV: Ivory intelligent, programmable sounder base.
B200S-LF-WH: White, low-frequency version of B200S.
B200S-LF-IV: Ivory, low-frequency version of B200S.
B200SR-WH: White intelligent programmable sounder base, Temporal 3 or Continuous tone. For retrofit installations replacing B501BH series bases.
B200SR-IV: Ivory intelligent programmable sounder base, Temporal 3 or Continuous tone. For retrofit installations replacing B501BH series bases.
B200SR-LF-WH: White, low-frequency version of B200SR.
B200SR-LF-IV: Ivory, low-frequency version of B200SR.
FMM-1: FlashScan monitor module.
FDM-1: FlashScan dual monitor module.
FZM-1: FlashScan two-wire detector monitor module.
FMM-101: FlashScan miniature monitor module.
FTM-1: Firephone Telephone Module connects a remote firefighter telephone to a centralized telephone console. Reports status to panel. Wiring to jacks and handsets is supervised.
FCM-1: FlashScan control module.
FCM-1-REL: FlashScan releasing control module.
FRM-1: FlashScan relay module.
FDRM-1: FlashScan dual monitor/dual relay module.
NBG-12LX: Manual pull station, addressable.
ISO-X: Isolator module.
ISO-6: Six fault isolator module.
XP6-C: FlashScan six-circuit supervised control module.
XP6-MA: FlashScan six-zone interface module; connects intelligent alarm system to two-wire conventional detection zone.
XP6-R: FlashScan six-relay (Form-C) control module.
XP10-M: FlashScan ten-input monitor module.
ENCLOSURES, CHASSIS, AND DRESS PLATES
CAB-5 Series Enclosure: CPU-N16LD and CPU-N16LND mount in a standard CAB-5 Series enclosure (available in 5 sizes, “A” through= “E”). Backbox and door ordered separately; requires BP-5 battery plate.
CA-2: Chassis for FACP control panel when DVC-EM is used with firefighter’s telephone. Mounts in the top two rows of a CAB-4 series enclosure.
DP-T2A: Dress panel for CAB-5 Series, mounts 10″ display and two ACM-30 annunciators.
DP-T2A-CB4: Dress panel for CAB-4 Series, mounts 10″ display and two ACM-30 annunciators.
DP-4A: Dress panel for CAB-5 Series, mounts four ACM-30 annunciators.
DP-BLN: Blank dress panel. Provides dead-front panel for unused tiers in a CAB-5 Series enclosure.
BP-5: Battery plate, required.
NFS-LBB: Battery Box. The NFS-LBB is used to mount up to two 55 AH batteries. Dimensions: Box: 24″ (610 mm) wide x 14″ (356 mm) high x 7.75″ (197 mm) deep. Door: 24.125″ (613 mm) wide x 14.25″ (362 mm) high; door adds 0.0625″ (approx. 1.6 mm) to depth.
CHS-CGW: Chassis for mounting the CGW-MBB in a CAB-4 or CAB-5 Series enclosure.
CHS-ADP: Adapter plate for mounting a CAB-4 chassis in a CAB-5 Series enclosure.
BACKBOXES
BB-100: Backbox for batteries and power supplies. The BB-100 mounts up to two 100 AH batteries and power supply, if needed. 30″ (76.20 cm) wide x 25″ (63.50 cm) high x 7.5″ (19.05 cm) deep; depth includes door.
BB-200: Backbox for batteries and power supplies. Holds up to four 100 AH batteries (200 AH capacity) and power supply. 30″ (76.20 cm) wide x 36″ (91.44 cm) high x 7.5″ (19.05 cm) deep; depth includes door.
ABB-1: Backbox for ACM-30 annunciator, 1 position.
ABB-2: Backbox for ACM-30 annunciator, 2 position.
NBB-2: Annunciator backbox, 2 position.
CLSS GATEWAY AND LICENSEABLE FEATURES
CGW-MBB: CLSS Gateway for Internet/cloud-based communication between the FACP and peripheral devices.
HON-CGW-MBB: CLSS Gateway, pre-installed in a cabinet.
Licenseable features: Individually purchased and downloaded to a specific panel.
- N16-CAC: Custom Action Button expansion. Adds 8 custom action buttons to an N16 panel (maximum 32 buttons).
- N16-CLIP: Enables CLIP mode on an N16 panel.
- N16-GZN: General Zone expansion. Adds 250 general zones to an N16 panel (maximum 2000 zones).
- N16-LGZ: Logic Zone expansion. Adds 250 logic zones to an N16 panel (maximum 2000 zones).
- N16-NWD: Enables Network Display Mode on an N16 panel to emulate NCD’s network display capabilities.
- N16-UZC: Universal Zone Coding, enables UZC for an N16 panel.
NOTE: For other options including compatibility with retrofit equipment, refer to the panel’s installation manual, the SLC manual, and the Device Compatibility Document.